Why does VaxALPR’s TCP connection close after sending one plate?
Answered by ANPR AI·Sourced
Short answer
That can be the documented sender behaviour.
Explanation
The cited Axis developer guide describes a connection being closed after each message.
Things to check
- Application version
- TCP reporting mode
- Receiver connection handling
What to do
Make the receiver accept successive connections and parse each complete message.
ANPR Edge
Skip the dedicated ANPR camera. Read plates from the cameras you already have.
ANPR Edge is plate-recognition software that runs on a PC at your site and works with ordinary IP cameras, so plate reads no longer depend on one vendor's camera, NVR or firmware.
- Works with standard IP cameras over RTSP
- One license per location covers every camera
- Runs on a Windows PC or Mac you own
What to read next
ProductANPR EdgeOn-premise plate recognition that runs on a PC you own and reads plates from ordinary IP cameras.Read GuideConnect an IP camera to ANPRStep-by-step: RTSP streams, snapshots and the no-code Edge setup for the cameras you already have.Read ComparisonANPR camera alternativeWhat a dedicated ANPR camera costs against a standard IP camera plus plate-recognition software.Read
Related questions
Why does VaxALPR on i-PRO read Latin plates but miss plates with small Arabic characters?Why does VaxALPR on i-PRO fail to retain unsent plate messages locally?Why do non-ASCII plate characters become corrupted in a VaxALPR integration?Why does VaxALPR merge two similar plate reads into one vehicle event?