Why is the same plate missing when it returns within a few minutes on an older Hikvision camera?

Answered by ANPR AI·Sourced

Short answer

A repeat-plate filter may suppress the second read.

Explanation

The historical IPC-H7 5.5.121 release notes describe a default-enabled filter with a four-minute default and a one-to-five-minute range.

Things to check

  • Exact firmware
  • Repeat filter
  • Time between visits

What to do

For this documented release, adjust the filter to suit return traffic and retest. Verify current firmware separately.

Source

Hikvision IPC-H7 firmware release notes

Scope and version

5.5.121 build 200427; historical firmware

ANPR Edge

Skip the dedicated ANPR camera. Read plates from the cameras you already have.